IMEMR
66.92
Volume 1, Issue 1 (2020)                   J Clinic Care Skill 2020, 1(1): 37-42 | Back to browse issues page
Article Type:
Original Research |

Print XML PDF HTML


History

How to cite this article
Rezaeikia R, Najafi Doulatabad S, Afrasiabifar A, Zoladl M. Effect of Passive Movements of Lower Extremity on Hemodynamic Parameters of the Patients under Ventilator. J Clinic Care Skill 2020; 1 (1) :37-42
URL: http://jccs.yums.ac.ir/article-1-29-en.html
Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rights and permissions
1- Student Research Committee, Yasuj University of Medical Sciences, Yasuj, Iran
2- School of Nursing, Yasuj University of Medical Sciences, Yasuj, Iran ‎
3- Medical Surgical Nursing Department, Yasuj University of Medical Sciences, Yasuj, Iran
4- Social Determinants of Health Research Center, Yasuj University of Medical Sciences, Yasuj, Iran
* Corresponding Author Address: School of Nursing, Yasuj University of Medical Sciences, Next to Emam Sajad Hospital, Shahid Jalil Boulevard, Yasuj, Iran. (najafi.shahla@yums.ac.ir)
Abstract   (3104 Views)
Aims: The present study was conducted with the aim of determining the effect of passive movements on hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse, and pulse pressure of patients under ventilation.
Materials & Method: In this controlled clinical trial, 64 patients under ventilation in Kohgiluyeh and Boyer-Ahmad University of Medical Sciences and Health Services and Shiraz University of Medical Sciences were selected by convenience sampling method. They were assigned to experimental (32 people) and control (32 people) groups, using random block assignment. The experimental group, in half supine position at 30°, received passive movements of the lower extremities, according to the protocol, by a therapist for 22 minutes. Then, the values of hemodynamic parameters were recorded after 22 minutes and at intervals of 2, 6, 12 and 24h after the post-test, as follow-up times. Data were analyzed by SPSS 21 software, using independent t-test, Chi-square test and repeated measure of variance analysis.
Findings: In hemodynamic parameters of the experimental group in each time interval, including immediately, 2 hours, 6 hours, 12 hours, and 24 hours after the completion of the research interventions, compared with their amount at the starting point of the study, and in comparison with these changes in the control group, there was no significant difference (p>0.05).
Conclusion: Passive movements of lower extremity have no effect on hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse, and pulse pressure of patients under ventilation.
 
Keywords:

References
1. Kasper DL, Fauci AS, Hauser S, Longo D, Jameson JL, Loscalzo J. Harrison's Principles of Internal Medicine. 19th edition. New York: McGraw-Hill Education; 2015. [Link]
2. Nakhjavani N. Evaluation of need for mechanical ventilation in children who hospitalized in PICU. J Babol Univ Med Sci. 2005;7(3):79-84. [Persian] [Link]
3. Behbahani S, KarimiMaridani M. Intensive care unit; Glimmer of hope for patients with acute condition. Med Lab Eng Mag. 2013;13(149):41-4. [Persian] [Link]
4. Zahmatkesh MM, Adeli SH, ValizadeHasanloei MA, Niakan-Lahidji M, Moradi-Moghadam O, Farazmand A, et al. A comparative study between S.I.M.V to T-piece and S.I.M.V to spontaneous breathing then T-piece in process of weaning of the patients from mechanical ventilator in intensive care unit. J Urmia Univ Med Sci. 2011;22(4):322-28. [persin] [Link]
5. Zojaji kohan MR, Ahasan B, Naseri K. Study on value of Arterial blood gas measurement in therapeutic process of patients with multiple trauma who were depend to mechanical ventilator with clinical stability. Sci J Kurdistan Univ Med Sci. 2005;10(2):55-60. [Persian] [Link]
6. Girard TD, Kress JP, Fuchs BD, Thomason JW, Schweickert WD, Pun BT, et al. Efficacy and safety of a paired sedation and ventilator weaning protocol for mechanically ventilated patients in intensive care (awakening and breathing controlled trial): A randomised controlled trial. Lancet. 2008;371(9607):126-34. [Link] [DOI:10.1016/S0140-6736(08)60105-1]
7. Borges JB, Okamoto VN, Matos GF, Caramez MP, Arantes PR, Barros F, et al. Reversibility of lung collapse and hypoxemia in early acute respiratory distress syndrome. Am J Respir Crit Care Med. 2006;174(3):268-78. [Link] [DOI:10.1164/rccm.200506-976OC] [PMID]
8. Merriam-Webster. Merriam-webster's medical dictionary. Springfield, Massachusetts: Merriam-Webster; 1995. [Link]
9. Behnam moghadam M, Azimian J, Abdi N, Mirzaee MS. Non invasive hemodynamic monitoring in critical care units: Review article. J Anesthesiol Pain. 2015;5(2):72-81. [Persian] [Link]
10. Valentin A, Ferdinande P, ESICM Working Group on Quality Improvement. Recommendations on basic requirements for intensive care units: Structural and organizational aspects. Intensive Care Med. 2011;37(10):1575-87. [Link] [DOI:10.1007/s00134-011-2300-7] [PMID]
11. Tobin MJ. Principles and practice of mechanical ventilation. Tobin MJ, editor. 3rd edition. New York: McGraw Hill Professional; 2012. [Link]
12. McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348(12):1123-33. [Link] [DOI:10.1056/NEJMra011883] [PMID]
13. Antonelli M, Conti G, Esquinas A, Montini L, Maggiore SM, Bello G, et al. A multiple-center survey on the use in clinical practice of noninvasive ventilation as a first-line intervention for acute respiratory distress syndrome. Crit Care Med. 2007;35(1):18-25. [Link] [DOI:10.1097/01.CCM.0000251821.44259.F3] [PMID]
14. Topp R, Ditmyer M, King K, Doherty K, Hornyak J 3rd. The effect of bed rest and potential of prehabilitation on patients in the intensive care unit. AACN Clin Issues. 2002;13(2):263-76. [Link] [DOI:10.1097/00044067-200205000-00011]
15. Westerdahl E, Lindmark B, Eriksson T, Hedenstierna G, Tenling A. The immediate effects of deep breathing exercises on atelectasis and oxygenation after cardiac surgery. Scand Cardiovasc J. 2003;37(6):363-7. [Link] [DOI:10.1080/14017430310014984] [PMID]
16. Genc A, Koca U, Gunerli A. What are the hemodynamic and respiratory effects of passive limb exercise for mechanically ventilated patients receiving low-dose vasopressor/inotropic support?. Crit Care Nurs Q. 2014;37(2):152-8. [Link] [DOI:10.1097/CNQ.0000000000000013] [PMID]
17. Brimioulle S, Moraine JJ, Norrenberg D, Kahn RJ. Effects of positioning and exercise on intracranial pressure in a neurosurgical intensive care unit. Phys Ther. 1997;77(12):1682-9. [Link] [DOI:10.1093/ptj/77.12.1682]
18. Loram L. The Cardiopulmonary effect of passive movement. S Afr J Physiother. 2002;58(3):27-32. [Link] [DOI:10.4102/sajp.v58i3.219]
19. Czell D, Schreier R, Rupp R, Eberhard S, Colombo G, Dietz V. Influence of passive leg movements on blood circulation on the tilt table in healthy adults. J Neuroeng Rehabil. 2004;1(1):4. [Link] [DOI:10.1186/1743-0003-1-4] [PMID] [PMCID]
20. Richard R, Staley M, Miller SF. The effect of extremity range of motion on vital signs of critically 111 patients and patients with burns: A Pilot Study. J Burn Care Res. 1994;15(3):281-4. [Link] [DOI:10.1097/00004630-199405000-00014]
21. Achugbue FS. The effects of therapeutic passive movement on cardiovascular response in stroke patients. Res J Med Sci. 2009;3(1):12-5. [Link]
22. Amidei C, Sole ML. Physiological responses to passive exercise in adults receiving mechanical ventilation. Am J Crit Care. 2013;22(4):337-48. [Link] [DOI:10.4037/ajcc2013284] [PMID]
23. Monnet X, Teboul JL. Passive leg raising. Intensive Care Med. 2008;34(4):659-63. [Link] [DOI:10.1007/s00134-008-0994-y] [PMID]
24. Venturelli M, Amann M, Layec G, McDaniel J, Trinity JD, Fjeldstad AS, et al. Passive leg movement‐induced hyperaemia with a spinal cord lesion: Evidence of preserved vascular function. Acta Physiol (Oxf). 2014;210(2):429-39. [Link] [DOI:10.1111/apha.12173] [PMID] [PMCID]
25. Savi A, Maia CP, Dias AS, Teixeira C. Hemodynamic and metabolic effects of passive leg movement in mechanically ventilated patients. Rev Bras Ter Intensiva. 2010;22(4):315-20. [Link] [DOI:10.1590/S0103-507X2010000400001] [PMID]
26. McDaniel J, Fjeldstad AS, Ives S, Hayman M, Kithas P, Richardson RS. Central and peripheral contributors to skeletal muscle hyperemia: Response to passive limb movement. J Appl Physiol (1985). 2010;108(1):76-84. [Link] [DOI:10.1152/japplphysiol.00895.2009] [PMID] [PMCID]
27. Fukuda S, Shimada K, Kawasaki T, Kono Y, Jissho S, Taguchi H, et al. "Passive exercise" using whole body periodic acceleration: Effects on coronary microcirculation. Am Heart J. 2010;159(4):620-6. [Link] [DOI:10.1016/j.ahj.2009.12.034] [PMID]
28. Thelandersson A, Volkmann R, Cider A. Blood flow velocity and vascular resistance during passive leg exercise in the critically ill patient. Clin Physiol Funct Imaging. 2012;32(5):338-42. [Link] [DOI:10.1111/j.1475-097X.2012.01132.x] [PMID]
29. Younis G, Sayed Ahmed S. Effectiveness of passive range of motion exercise on hemodynamic parameters and behavioral pain intensity among adult mechanically ventilated patients. IOSR J Nurs Health Sci. 2015;4(6):47-59. [Link]
30. Koch SM, Fogarty S, Signorino C, Parmley L, Mehlhorn U. Effect of passive range of motion on intracranial pressure in neurosurgical patients. J Crit Care. 1996;11(4):176-9. [Link] [DOI:10.1016/S0883-9441(96)90028-3]
31. Pires-Neto RC, Kawaguchi YMF, Hirota AS, Fu C, Tanaka C, Caruso P, et al. Very early passive cycling exercise in mechanically ventilated critically ill patients: Physiological and safety aspects--a case series. PLoS One. 2013;8(9):e74182. [Link] [DOI:10.1371/journal.pone.0074182] [PMID] [PMCID]
32. Marino PL. Marino's The ICU Book. Alphen aan den Rijn: Wolters Kluwer Health; 2013. [Link]
33. Asgari MR, Soleimani M. Comprehensive book on intensive nursing care in ICU,CCU and dialysis wards. 3th edition. Tehran: Boshra; 2004. [Persian] [Link]